Skip to content Skip to navigation

Specifications

Connection electrical comms interface connector RJ45 (FCC 68) - Female
Connection Inlet Flange DN 40 CF (2.75")
Pressure Measurement Max 1.00
Pressure Measurement Min 1.000 × 10⁻⁷

AIM-SL - DN 40 CF - St St, Active Inverted Magnetron Gauge, D14664000

Part Number: D14664000

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Connection Inlet Flange
D1464200C DN 25 ISO-KF (NW25)
D1464400C DN 25 ISO-KF (NW25)
D1464500C DN 25 ISO-KF (NW25)
D1466100C DN 40 CF (2.75")
D1466200C DN 40 CF (2.75")
D14664000 DN 40 CF (2.75")
D1466400C DN 40 CF (2.75")
D1466500C DN 40 CF (2.75")
D14671000 DN 25 ISO-KF (NW25)

Gauge Indirect Pressure Measurement

Indirect braod range vacuum gauges are the best choice when the pressure needs to be measured over a wide range and when good accuracy is needed across the whole range. Reliable vacuum gauges are essential to ensure your system’s accuracy and control. Our vacuum gauging solutions include the WRG Series Cold Cathode Combination Gauge, AIM Series Cold Cathode Gauge, and APG Series Pirani Gauge.

AIM Series Cold Cathode Gauge

Edwards Active Inverted Magnetron (AIM) Gauges provide accurate measurement over the vacuum range of 1 x 10-2 to 1 x 10-9 mbar. These gauges have proved to be rugged and reliable in a wide range of applications, ranging from scientific instruments to industrial processes.

 

AIM-S gauges offer an S-shaped analog signal output. The AIM-X Gauge is an inverted magnetron gauge head and gauge controller combined into a single compact unit, and features a linear output for easy integration with a computer or PLC.

 

The SL or XL variants have a very low external magnetic field, these are ideally suitable for use with sensitive analytical instruments or in applications where the gauge needs to be mounted in close proximity to a turbomolecular pump.

Features and Benefits

  • Drive electronics combined in the gauge head which reduces the system cost and saves valuable rack space.
  • Low output impedance and integral Faraday shield provides high level of noise immunity and permits long cable runs (up to 100 m).
  • Low magnetic field version – XL – for sensitive applications, e.g. mass spectrometry and electron microscopy.
  • Interchangeable body tube allows for rapid tube replacement without pre-calibration.
  • CSA, CSA/US approved – meets safety requirements for electrical equipment for measurement.

General Product Information

Connection Inlet Flange DN 40 CF (2.75")
Weight 0.810
Power Supply Voltage DC 13.5-36V
Dimension Length 0.079
IP Rating IP40
Power Supply Frequency DC Voltage
Dimension Height 0.125
Dimension Width 0.079
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.

Environmental Conditions

Temperature Ambient Operation Max 333.15
Temperature Ambient Operation Min 278.15
Temperature Ambient Storage Min 273.15
Temperature Ambient Storage Max 343.15

Classification

Classification Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Ultra High Vacuum: 1·10⁻⁷ - 1·10⁻¹¹ mbar
Classification Principle of Measurement Cold-cathode vacuum gauge (IM inverted magnetron)

Performance Data

Measurement Uncertainty >1x10-8 mbar ±30%
Power consumption Max String 2W
Pressure Measurement Max 1.00
Pressure Measurement Min 1.000 × 10⁻⁷

Operation Conditions - Limitations

Temperature Baking Max (Elec. Removed) 573.15
Pressure Inlet Max Overpressure 1.000 × 10⁶

Connectivity - Communication Interface

Communication Interfaces Customer 0-10 V (analog output - S-shape)
Connection electrical comms interface connector RJ45 (FCC 68) - Female
Setpoint Quantity 1
Status Indicator LED

Variants

Variant Gauges AIM-SL (S-shape 0-10V output, low magnetic stray field)