Specifications
Connection electrical comms interface connector | RJ45 (FCC 68) - Female |
Connection Inlet Flange | DN 25 ISO-KF (NW25) |
Pressure Measurement Max | 1.00 |
Pressure Measurement Min | 1.000 × 10⁻⁷ |
AIM-X - NW25 - St St - factory calibration, Active Inverted Magnetron Gauge, D1464200C
Variant
Explore the range of variants given below to compare the product
Short Description | Part Number | Connection Inlet Flange |
---|---|---|
D1464200C | DN 25 ISO-KF (NW25) | |
D1464400C | DN 25 ISO-KF (NW25) | |
D1464500C | DN 25 ISO-KF (NW25) | |
D1466100C | DN 40 CF (2.75") | |
D1466200C | DN 40 CF (2.75") | |
D14664000 | DN 40 CF (2.75") | |
D1466400C | DN 40 CF (2.75") | |
D1466500C | DN 40 CF (2.75") | |
D14671000 | DN 25 ISO-KF (NW25) |
Gauge Indirect Pressure Measurement
Indirect braod range vacuum gauges are the best choice when the pressure needs to be measured over a wide range and when good accuracy is needed across the whole range. Reliable vacuum gauges are essential to ensure your system’s accuracy and control. Our vacuum gauging solutions include the WRG Series Cold Cathode Combination Gauge, AIM Series Cold Cathode Gauge, and APG Series Pirani Gauge.
AIM Series Cold Cathode Gauge
Edwards Active Inverted Magnetron (AIM) Gauges provide accurate measurement over the vacuum range of 1 x 10-2 to 1 x 10-9 mbar. These gauges have proved to be rugged and reliable in a wide range of applications, ranging from scientific instruments to industrial processes.
AIM-S gauges offer an S-shaped analog signal output. The AIM-X Gauge is an inverted magnetron gauge head and gauge controller combined into a single compact unit, and features a linear output for easy integration with a computer or PLC.
The SL or XL variants have a very low external magnetic field, these are ideally suitable for use with sensitive analytical instruments or in applications where the gauge needs to be mounted in close proximity to a turbomolecular pump.
Features and Benefits
- Drive electronics combined in the gauge head which reduces the system cost and saves valuable rack space.
- Low output impedance and integral Faraday shield provides high level of noise immunity and permits long cable runs (up to 100 m).
- Low magnetic field version – XL – for sensitive applications, e.g. mass spectrometry and electron microscopy.
- Interchangeable body tube allows for rapid tube replacement without pre-calibration.
- CSA, CSA/US approved – meets safety requirements for electrical equipment for measurement.
General Product Information
Connection Inlet Flange | DN 25 ISO-KF (NW25) |
Weight | 0.810 |
Power Supply Voltage | DC 13.5-36V |
Dimension Length | 0.079 |
IP Rating | IP40 |
Power Supply Frequency | DC Voltage |
Dimension Height | 0.116 |
Dimension Width | 0.079 |
Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
Environmental Conditions
Temperature Ambient Operation Max | 333.15 |
Temperature Ambient Operation Min | 278.15 |
Temperature Ambient Storage Min | 273.15 |
Temperature Ambient Storage Max | 343.15 |
Classification
Classification Product Pressure Range |
High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Ultra High Vacuum: 1·10⁻⁷ - 1·10⁻¹¹ mbar |
Classification Principle of Measurement | Cold-cathode vacuum gauge (IM inverted magnetron) |
Performance Data
Measurement Uncertainty | >1x10-8 mbar ±30% |
Power consumption Max String | 2W |
Pressure Measurement Max | 1.00 |
Pressure Measurement Min | 1.000 × 10⁻⁷ |
Operation Conditions - Limitations
Temperature Baking Max (Elec. Removed) | 423.15 |
Pressure Inlet Max Overpressure | 1.000 × 10⁶ |
Variants
Variant Gauges | AIM-X (linear analog 0-10V output) |
Certificated Pressure Measurement Device | Internal Factory Calibration |
Connectivity - Communication Interface
Communication Interfaces Customer | 0-10 V (analog output - S-shape) |
Connection electrical comms interface connector | RJ45 (FCC 68) - Female |
Setpoint Quantity | 1 |
Status Indicator | LED |
- D14641856 - Instructions.pdf - Brazilian Portuguese - Instructions
- D14641851 - Instructions.pdf - Czech - Instructions
- D14671851 - Instructions.pdf - Czech - Instructions
- D14641886 - Instructions.pdf - Dutch - Instructions
- D14671886 - Instructions.pdf - Dutch - Instructions
- D1G1091100-A00_A_APG200_-_XM-DN16CF_CUSTOMR_REF.stp - English - Drawings
- D14545840 - Service Instructions.pdf - English - Instructions
- D14611880 - Instructions.pdf - English - Instructions
- D14643880 - Instructions.pdf - English - Instructions
- NRA737880 - Instructions.pdf - English - Instructions
- D14671880 - Instructions.pdf - English - Instructions
- NRB441880 - Amendment.pdf - English - Instructions
- D14558880 - Instructions.pdf - English - Instructions
- D14558840 - Service Instructions.pdf - English - Instructions
- P60030620 - Amendment.pdf - English - Instructions
- 3601-0754-01-AIM200-Datasheet.pdf - English - Technical Data
- D14545885 - Instructions.pdf - English, French, German - Instructions
- D14641885 - Instructions.pdf - English, French, German - Instructions
- D14641883 - Instructions.pdf - French - Instructions
- D14641882 - Instructions.pdf - German - Instructions
- D14558882 - Instructions.pdf - German - Instructions
- D14641849 - Instructions.pdf - Hungarian - Instructions
- D14641884 - Instructions.pdf - Italian - Instructions
- D14641852 - Instructions.pdf - Polish - Instructions
- D14641854 - Instructions.pdf - Romanian - Instructions
- D14641857 - Instructions.pdf - Russian - Instructions
- D14641888 - Instructions.pdf - Spanish (European) - Instructions